Ceramic fiber pipe shells are high-temperature-resistant pipe insulation materials made from ceramic fiber wool, suitable for medium- and high-temperature applications such as industrial furnaces, thermal pipelines, and steam lines. The parameters of this product are derived from a commissioned inspection report by Hebei Quanhe Insulation Building Materials Co., Ltd. (Report No. JXT2026253136, Guangdong Junxin Testing Co., Ltd., CNAS L24868, 2026.05.08). The tested sample (primary test model 100kg/m³ - Φ76×50×1000mm) measured a thermal conductivity of 0.139 W/(m·K)@500°C (board specimen), shot content of 2.7%, and combustion performance Class A (A1, non-combustible). ⚠️ Important note: The above test temperature of 500°C for the 0.139 W/(m·K) value is the thermal conductivity test temperature for the "board specimen," and is not the upper limit of the service temperature for the pipe shell itself. The actual applicable temperature of ceramic fiber pipe shells must be based on the specific model and the national standard GB/T 16400. It is strictly prohibited to state that "ceramic fiber pipe shells withstand 500°C." The test results are valid only for the samples tested.
| Density | 100 kg/m³ (measured on the tested sample; primary test model 100kg/m³-Φ76×50×1000mm) |
| Material | Aluminum silicate wool |
| Specifications | Tested sample Φ76×50×1000mm; the report lists multiple models such as 48/60/89/108/133mm×50mm |
| Certification | Entrusted Inspection · CMA/CNAS (Guangdong Junxin CNAS L24868, Report No. JXT2026253136) |
| Service temperature | The specific model shall comply with the national standard GB/T 16400; 500°C is the thermal conductivity test temperature for the board specimen, not the maximum temperature resistance of the pipe section (it is prohibited to state "withstands 500°C"). |
| Thermal conductivity | 0.139 W/(m·K) @500℃ (thermal conductivity test on board specimen, not pipe section temperature resistance; Report JXT2026253136) |
| Executive Standard | GB/T 16400-2015 (Aluminosilicate wool and its products for thermal insulation), GB 8624-2012 |
| Fire rating | Class A (Class A1, non-combustible, GB 8624-2012) |
Report No.:JXT2026253136 | Issuing Body:Guangdong Junxin Testing Co., Ltd.(CNAS L24868) | Issue Date:2026-05-08 | Commissioned testing
Tested Sample:Main tested size Φ76×50×1000 mm; nominal density marked on the model 100 kg/m³; test basis GB 8624-2012 and GB/T 16400-2015
| Test Item | Measured Value | Standard Limit | Verdict |
|---|---|---|---|
| Thermal conductivity (mean temperature 500°C) | 0.139 W/(m·K) | ≤0.161 | Complies |
| Shot content | 2.7 % | ≤20.0 | Complies |
| Moisture content | 0.3 % | ≤1.0 | Complies |
| Permitted deviation of bulk density | 4 % | ≤15 | Complies |
| Reaction to fire class | A1 (GB 8624-2012) | — | Furnace temperature rise 14°C / flaming 0 s |
| Maximum service temperature | Not tested | — |
The tested sample measured 0.139 W/(m·K) at a test temperature of 500℃ (board sample), per commissioned test report JXT2026253136 (Guangdong Junxin, CNAS L24868).
No. 500℃ is the thermal-conductivity test temperature of a board sample, not the service temperature limit of the pipe shell. The actual service temperature depends on the specific model and GB/T 16400; do not claim "withstands 500℃".
The tested sample achieved Class A (A1, non-combustible) per GB 8624-2012, suitable for medium-to-high temperature industrial piping.
The report lists models 48/60/89/108/133mm×50mm etc., with the main tested size Φ76×50×1000mm. Custom sizes by pipe outer diameter are supported; contact sales for MOQ and lead time.
| Not tested for the pipe section in this report |